IEC 63171 pdf free download
IEC 63171 pdf free download.Connectors for electrical and electronic equipment – Shielded or unshielded free and fixed connectors for balanced single-pair data transmission with current-carrying capacity – General requirements and tests.
The category is indicated by a series of three groups of digits separated by oblique strokes corresponding respectively to the temperature in the cold test and that in the dry heat test, and the number of days of exposure to damp heat (steady state) the components will withstand, as follows:
First set: two digits denoting the minimum ambient temperature of operation (cold test). Where the temperature requires the use of only one digit, it shall be prefixed by the figure ‘0” for a negative temperature or the symbol +“ for a positive temperature to make up the two-character group.
Second set: three digits denoting the maximum ambient temperature of operation (dry heat test). Where the temperature requires the use of only two digits, they shall be prefixed by the figure “0 to make up the three-digit group.
Third set: two digits denoting the number of days of the damp heat, steady-state test (Test Ca). Where the duration requires the use of only one digit, it shall be prefixed by the figure “0 to make up the two-digit group. The figures 00 shall be used to indicate that the component is not required to be exposed to damp heat (steady state).
In order to belong to a given category, components shall comply with the requirements of the relevant specification when subjected to the whole set of tests prescribed for their category.
5.4 Electrical characteristics
5.4.1 Creepage and clearance distances
The permissible operating voltages depend on the application and the specified safety
requirements.
Although insulation coordination is not required for safety aspects by the connector covered in this document and in the relevant detail product specification, it is still required for electrical functional requirements.
In general, for minimum values of clearances and creepage distances, IEC 60664-1 shall apply, based on the assigned voltage rating 50 V AC and 60 V DC.
NOTE As indicated in IEC 60664-1, IEC TR 63040 provides an alternative and more precise dimensioning procedure for clearances equal to or less than 2 mm.
The creepage and clearance distances given in the relevant detail product specification apply for mated connectors.
The creepage and clearance distances that cover performance requirements in IEC 60664-1 may be reduced, based on IEC TR 63040.
Furthermore, in practice, based on the conductive pattern of the printed board or the wiring used, reductions in creepage or clearance distances are permitted.
5.4.2 Voltage proof
Conditions:
— IEC 60512-4-1, Test 4a, Method A.
— Standard atmospheric conditions.
— Mated connectors.
All variants:
— 1 000 V DC: contact to contact.
— 1 500 V AC (RMS at 50 Hz to 60 Hz) or 2 250 V DC: all contacts connected together, to shield (if applicable).
NOTE For connector interfaces providing more than one individual 2-way shielded connector, the test is repeated on each of these individual connectors.
Compliance with this document, with respect to transmission characteristics, shall be determined in accordance with specified test methods described in test group FP. AlI transmission performance requirements shall apply between the reference planes specified in IEC 60512-28-100. All transmission performance results shall be reported as worst-case overall result after testing all samples.IEC 63171 pdf download.