IEC TR 63036 pdf free download.Electrical interface specification for phase-cut dimmer in phase-cut dimmed lighting systems.
Required minimum number of controlgear connected with one phase-cut dimmer (named in phase-cut dimmer installation sheet)
Rated input power of the controlgear (as marked)
Maximum permissible nominal load of phase-cut dimmer (according to the installation sheet)
Minimum nominal load required by phase-cut dimmer (according to the installation sheet)
Resistance value of ohmic load R in relation to the relevant mains voltage according to Tables 7 to 11, representing the maximum permissible load of phase-cut dimmer
ax
Absolute value of the slew rate of the decrease of the voltage across the input terminals of a controlgear in trailing edge dimming mode when the phase-cut dimmer switches off at time tsl (see Figure 3)
Absolute value of the slew rate of the increase of the voltage across the input terminals of a controlgear in leading edge dimming mode when the phase-cut dimmer under test switches on (according to Clause 8)
Absolute value of the slew rate of the decrease of the voltage across the input terminals of a controlgear in trailing edge dimming mode when the phase-cut dimmer under test switches off (according to Clause 8)
Time related to previous zero crossing of the mains to the subsequent zero crossing of the mains (duration of a half wave)
Time related to previous zero crossing of the mains when leading edge phase-cut dimmer reduces its impedance towards zero by activating its power switch
Time related to previous zero crossing of the mains when trailing edge phase-cut dimmer increases its impedance towards infinite by deactivating its power switch
Time related to previous zero crossing of the mains when the voltage 1CG falls below ‘SW in trailing edge method
Time related to previous zero crossing of the mains when the transition from the conducting period to the non-conducting period is finished
Time related to previous zero crossing of the mains when voltage 1CG crosses
Transition time for trailing edge mode, equals 1s2 — ‘si
Voltage across the input terminals of the controlgear (see Figure 1)
Voltage between the line side (L) and load side terminal of the phase-cut dimmer (see Figure 1)
Mains voltage (rated nominal value)
Phase-cut voltage for testing purposes, sinusoidal part of the waveform (i to HW’ 0 to I) equivalent to mains voltage
Lower limit for voltage across the input terminals of the controlgear to provide a current carrying capability ‘P0 during the electronic off state
Voltage across the input terminals of the controlgear at the time that leads to disabling (1’M(’) > 1’sw) or enabling (1’M(’) < I’) a current path having a current carrying capability of ‘CG SL or ‘CG STH
Value of test voltage (according to 8.3 of IEC TR 63037:—)
Instantaneous values of current or voltage
Impedance across the input terminals of the controlgear
Impedance between the line side (L) and the load side terminals of the phase-cut dimmer
Maximum impedance between the line side (L) and load side terminal of the phasecut dimmer, defined by the technical properties of the phase-cut dimmer